Electrical Power Distribution

Electric power distribution is electricity power being carried from the transmission system to the consumers. This final stage of delivery of electric power distributes power through substations that connect to the transmission system and lower the transmission voltage to medium voltage ranging between 2 kV and 35 kV with the use of transformers.

Primary distribution lines carry this medium voltage power to distribution transformers located near the consumer premises. Distribution transformers again lower the voltage to the utilization voltage used by lighting, industrial equipment or household appliances. All of this equipment used in this process needs protection from surges.

We provide a range of Medium Voltage silicone housed Surge Arresters (ASMSVL Series) and a unique complementary range (PDTISA18) which functions as an arrester and support Insulator also our SVL series provides protection from over-voltages on cable sheaths by the cross-bonding of the sheaths and the ground continuity conductor. These ranges of 10kA Class 1 distribution arresters are fully tested and approved to EN 60099-4 and IEC 61109.

ASMSVL Series - Silicone Moulded Sheath Voltage Limiter - Medium / High Voltage - 5kV to 45kV rms

Silicone Housed Gapless Surge Arrestor - Applicable to MV distribution systems and approved to EN 60099-4.  Rated Voltages from 5.0 to 45.0kVrms.  Various termination accessories available.

LVA415-5 - Low Voltage Arrester - 415V rms

Designed for use on AC or DC supply lines as an effective means of providing protection against lightning and switching induced overvoltages.

PDLV Series - Low Voltage Surge Arresters - 280V to 660V rms

The PDLV Series is a range of low voltage surge arresters are intended for protection of low voltage systems against overvoltages caused by lightning strikes and switching operations.

PDLV-D - Low Voltage Surge Arrester Disconnect - 280V to 660V rms

PDLV-D low voltage surge arresters with integrated thermal disconnect are intended for protection of low voltage systems

PDTISA18 - Tension Insulated Surge Arrester - Medium Voltage - 18kV rms

Combined Tension Insulator & Surge Arrestor - Applicable to MV distribution systems and approved to EN 60099-4.  Rated Voltage range can be extended on demand.

PSMV60 - Medium Voltage - 1 kVrms (Ur) to 14 kVrms (Ur)

PD Devices design and manufacture this PSMV60 range of metal oxide varistors (MOV) devices and therefore the ratings can usually be designed to suit any given application.

PSVL Series - Sheath Voltage Limiters - Medium Voltage - 3kV to 12kV rms

The PSVL is fully tested and approved to meet the requirements of CIGRE recommendations and IEC 60099-4

PDSVL60 Series - Sheath Voltage Limiters Medium Voltage - 1kV to 12kV rms

Designed, manufactured and tested here in the UK, this range of metal oxide varistor (MOV) devices and ratings can usually be designed to suit any given application.

SBM440 MOV Arrester without Gap - Low Voltage - 440V rms

The SBM440 is a low capacitance MOV arrester

SBM660 MOV Arrester without Gap Low Voltage - 660V rms

The SBM660 is a low capacitance MOV arrester

SBMG440 Low Capacitance Gapped Arrester Low Voltage - 440V rms

The SBMG440 is a low capacitance gapped metal oxide arrester

SBMG660 Low Capacitance Gapped Arrester Low Voltage - 660V rms

The SBMG660 is a low capacitance gapped metal oxide arrester

SVL03 - Sheath Voltage Limiter Low Voltage 300V rms

A Sheath Voltage Limiter component for the cross-bonding of cable sheaths and ground continuity conductor

SVL4 - Sheath Voltage Limiter Low Voltage 400V rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL06 - Sheath Voltage Limiter Low Voltage 600V rms

A Sheath Voltage Limiter component for the cross-bonding of cable sheaths and ground continuity conductor.

SVL8 - Sheath Voltage Limiter Low Voltage 800V rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL9.6 - Sheath Voltage Limiter - Low Voltage - 960V rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL16 - Sheath Voltage Limiter - Medium Voltage - 1.6kV rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL21 - Sheath Voltage Limiter - Medium Voltage - 2.1kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL28 - Sheath Voltage Limiter - Medium Voltage - 2.8kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL30 - Sheath Voltage Limiter - Medium Voltage - 3kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL32 - Sheath Voltage Limiter - Medium Voltage - 3.2kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL45 - Sheath Voltage Limiter Medium Voltage - 4.5kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.

SVL50 - Sheath Voltage Limiter Medium Voltage - 5kV  rms

Often, conductive structures like pipelines, data lines and physical entities such as fencing and barriers, run parallel to Overhead or Underground power transmission lines. In these situations, dangerous and damaging voltages can be induced as a function of normal operating or fault currents.