Type 2 - Class II / Type 3 -  Class III - 6kA SAD, 40kA MOV - Single & Three Phase - 1 to 4 Pole - Remote & Non Remote

A series of modular surge protection devices for the over-voltage protection of equipment connected to the incoming low voltage AC power supply.

Type 1 - Class I / Type 2 - Class II - Single Phase - 1 Pole - 12.5kA - 75VAC

The T1PD1/12.5/75R is a lightning surge arrester type 1 or type 2 according to EN 61643-11.

The main use of T1PD1/12.5/75R arrester is in structures of LPL III – IV according to EN 62305, e.g. residential houses with cable supply and subdistribution boards of big industrial structures and elimination of switching surges that originate in power supply systems.

Type 1 - Class I / Type 2 - Class II - Single Phase - 25kA - 48VDC

The T1PD1/25/48DCR is a type 1 - class I or type 2 - class II 48V DC surge protector designed to protect equipment connected to DC power supplies from lightning surges.

Type 1 - Class I / Type 2 - Class II - Single Phase - 1 Pole - 7kA - 75VAC

These SPDs are designed for use in the LPZ Concept at the boundaries of LPZ 0 – 1. For use in residential houses with cable supply and subdistribution boards of big industrial structures. These arresters are mainly intended for use in TNC systems.

Type 1 - Class I - Single Phase - 1 Pole - 12.5kA - 320VAC 

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use on the power supply lines, which operate a TN-C, TN-S and TT earthing system.

Type 1 - Class I / Type 2 - Class II - Single Phase - 1 Pole - 12.5kA - 500VAC

These devices are single-pole lightning and surge arresters Type 1+2 according to IEC EN 61643-11.

Type 1 - Class I - Single Phase - 50kA - 255VAC

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use in systems that use TN-C earthing. For TNS and TT systems it is necessary to combine these arresters with an additional module designed for Neutral – Earth use.

Type 1 - Class I - Single Phase - 50kA - 440VAC

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use in systems that use TN-C earthing. For TNS and TT systems it is necessary to combine these arresters with an additional module designed for Neutral – Earth use.

Type 2 - Class II - Single Phase - 1 Pole - 20kA - 270VAC

The T2PD1/20/275 & T2PD1/20/275R (remote version) are non moduler single-pole, metal oxide varistor surge arresters, Type 2 - Class II according to EN 61643-11 and IEC 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2.

Type 2 - Class II - Single Phase - 1 Pole - 20kA - 120VDC

The T2PDM1/20/120DC & T2PDM1/20/120DCR are single-pole, metal oxide varistor surge arresters, Type 2 according to IEC EN 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2.

Type 2 - Class II - Single Phase - 1 Pole - 20kA - 24VDC

The T2PDM1/20/24DC and T2PDM1/20/24DCR are single-pole, metal oxide varistor surge arresters, Type 2 according to IEC EN 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2.

Type 2 - Class II - Single Phase - 1 Pole - 20kA 275VAC

The T2PDM1/20/275 & T2PDM1/20/275R are single-pole, metal oxide varistor surge arrester, Type 2 according to EN 61643-11 and IEC 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2.

Type 2 - Class II - Single Phase - 1 Pole - 20kA - 48VDC

The T2PDM1/20/48DC and T2PDM1/20/48DCR are single-pole, metal oxide varistor surge arresters, Type 2 according to IEC EN 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2.

Type 2 - Class II - Single Phase - 1 Pole - 40kA - 440VAC

The main use of the T2PDM1/40/440R arrester is in all kinds of industry, residential and administration buildings. They are to be placed into the subsidiary switchboards or control boxes.

Type 2 - Class II - Single Phase - 1 Pole - 20kA L/N - 20kA N/PE - 275VAC

Type 2 Surge Arresters - Pluggable modular SPD Class II (Class C) for TN power supply systems. Non remote and remote versions available

Type 1-Class I/Type 2-Class II/Type 3-Class III- Single Phase-25kA-275VAC

A 25kA single-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection.

Type 1 - Class I / Type 2 - Class II - Single Phase - 2 Pole - 12.5kA -12.5kA - 275VAC

Recommended for use in the Lightning protection zones concept at the boundaries of LPZ 0-1. These lightning arresters are for use mainly in the power supply lines, which are operated as TN-S system.

Type 1 - Class I / Type 2 - Class II - Single Phase - 2 Pole - 12.5kA - 25kA - 230VAC

The T1PDM1/12.5/25/230 and the T1PDM1/12.5/25/230R are two-pole, Type 1 and 2 MOV + GDT lightning arrester according to EN 61643-11 and IEC 61643-11. The use of these arresters is mainly in the power supply lines, which are operated as TN-S and TT systems.

Type 1 - Class I / Type 2 - Class II - Single Phase - 12.5kA - 275VAC

A single-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use in industrial & administration buildings, schools, supermarkets and cathedrals.

Type 2 - Class II - Single Phase - 2 Pole - 20kA L/N - 40kA N/PE - 385VAC

The T2INM1/20/40/385 and the T2INM1/20/40/385R (remote version ) are for installation at LPZ 0B -1 or higher, protecting low voltage equipment from surge damage. Designed according to IEC 61643-11 / GB 18802.1.

This device has a pluggable modular SPD Class II (Class C) for TT and TN power supply system.

Type 2 - Class II / Type 3- Class III - Single & Three Phase - 10kA - 230VAC

A Surge Protection for distribution panels which supply mainframe computers, PABX systems and network servers is available from the compact 10kA 6651C Protector.

This hardwired, panel mounting surge protector with redundant protection and full protection status monitoring is available in single and three phase versions.

Type 1 - Class I / Type 2 - Class II / Type 3 - Class III - Single & Three Phase 40kA Surge Arresters 

These are hardwired single and three phase distribution panel protectors with 40kA of surge capacity and two stage (redundant) protection and provide pre-failure indication.

Type 1 - Class I / Type 2 - Class II / Type 3 - Class III Single & Three Phase 40kA Surge Arresters

The DSP600 Series L & N types have site fault condition indicators and relay contacts, which provide remote indication of protection status.

Type 3 - Class III - 1.5kA - 3kA L+N-PE - 230VAC - Audible SPD

A flexible solution to protecting individual pieces of equipment. Perfectly suited to protecting – ring mains & individual sockets, switch fuse spurs, lighting, fire alarm panels, CCTV cameras etc.

With Lightning Protection System Present 

An example of high rise residential block with LPS (Lightning Protection System) installed.

The specification of the CLASS I SPD will depend on the LPS installed.eg: Level I, II, III, IV

A TYPE 1 / CLASS I SPD is essential for any system that is required to comply with BS EN 62305.

We recommend a co-ordinated approach where further, down stream protection is installed to prevent damage to sensitive equipment connected to consumer units.

With No Lightning Protection System Present

Single Phase - Domestic Installation in High Rise Flats

This example shows a high rise residential block without LPS (Lightning Protection System) installed and the DNO (Distribution Network Operator) Supplied is via underground.

No LPS means that a TYPE 1 / CLASS I SPD is not required, how ever a TYPE 2 / CLASS II SPD should be installed to prevent damage to any electronics within the building from transient overvoltages created by non atmospheric conditions, eg: switching surges etc.

A secondary TYPE 2 / CLASS II SPD should also be considered due to equipment distance from original source of protection and the risk of damage should the incoming SPD sacrifices itself and leave the installation with no protection.

We would always recommend a co-ordinated approach where further, downstream protection is installed to prevent damage to sensitive equipment connected to consumer units.