All-Mode SPD 120V rms/DC PADs Approved (DSP1A/SSI/120AC)
|
PADs 0086-000060
Nominal 120V rms or DC All-Mode Protection
Operating Voltage 90 to 150V rms or DC
Solid State Interlocking (SSI) Protection
Hardwearing steel housing
DSP1A/SSI/120AC 120V All-Mode Surge Arrester for Solid State Interlocking (SSI) Protection with MOV or SAD and combination component technologies. Suitable for AC & DC systems, protection for signals, points, level crossings etc. Network Rail PADS Approved (PADS No.0086-000060) |
Download
|
|
Type 2, 90kA, 150kA, 300kA Three Phase (MDSP Series)
|
Type 2 - Class II - 90kA, 150kA, 300kA - Three Phase
A range of distribution panel protectors for single and three phase power systems, featuring exceptionally high surge handling capabilities of 90,150 and 300kA.The MDSP is intended for high exposure areas and critical systems where long life and low maintenance are required. |
Download
|
|
1 Channel 30000A EMP Protection (ZOMM 141/XXX/4/1 Series)
|
Range of 1 Channel EMP Devices
Continuous Operating Voltage 50V to 600V AC rms
4 Active MOV Per Line
Repetetive Duty 4/20μs 5000A
Max 8/20μs Current per Channel 30000A
ZOMM141/XXX/4/1 Series - A range of robust 1 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage 50V to 600V AC rms. Maximum Current per Channel 8/20μs 30000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
1-4 MOV Single Phase Assemblies (AZA-XP-S-V)
|
Customisable To Suit Any Specification
Nominal Reference Voltage DC 1320 & 1920
Max Continuous Operating Voltage 595 & 865 AC
Max Continuous Operating Voltage 830 & 1210 DC
Max Current 4/10μs Impulse 80kA x No Discs
AZA-XP-S-V - A customisable range of transient surge protection devices for industrial equipment applications. A wide range or voltage ratings available, typically 800V to 3000V. Operational features include low clamping voltage with a fast response to steep front impulse voltages.Heavy duty mounting brackets. 2 part epoxy coating for environmental protection. |
Download
|
|
10 Way Surge & Noise Protected IEC 19" Rack PDU (1048IEC/GB)
|
10 Way IECSockets
Powder Coated Steel Housing
Surge & Noise Protected
19 Inch Rack Mounted
ON/OFF Switch and Power Indication
1048IEC/GB 10 Way, Surge protected socket strip meets the requirements of BS EN61643-11/12 – Type 3, Class III. With a hardwired 2m lead and BS1363 (UK) moulded plug, and housed in durable powder coated steel, it features an ON/OFF switch, power indictaion and noise filter and is suitable for audio/video, IT or datacommunications systems. |
Download
|
|
10 Way Surge & RFI Protected IEC 19" Rack PDU (1038IEC/GB)
|
10 Way IECSockets
Powder Coated Steel Housing
Surge & RFI Protected
19 Inch Rack Mounted
ON/OFF Switch and Power Indication
1038IEC/GB 10 Way IEC socket strip with a hardwired 2m lead and GB (UK) BS1363 moulded plug. Surge protected power distribution unit meets the requirements of BS EN61643-11/12 – Type 3, Class III. Housed in durable powder coated steel, it features an ON/OFF switch, power indication and RFI filter and is suitable for audio/video, IT or datacommunications systems. |
Download
|
|
10 Way Surge Protected IEC 19" Rack PDU (1028IEC/GB)
|
10 Way IECSockets
Powder Coated Steel Housing
Surge Protected
19 Inch Rack Mounted
ON/OFF Switch and Power Indication
1028IEC/GB 10 Way IEC socket strip with a hardwired 2m lead and GB (UK) BS1363 moulded plug. Surge protected power distribution unit meets the requirements of BS EN61643-11/12 – Type 3, Class III. Housed in durable powder coated steel, it features an ON/OFF switch and power indication and is suitable for audio/video, IT or datacommunications systems. |
Download
|
|
10 Way Switched IEC 19" Rack Power Distribution Unit (1008IEC/GB)
|
10 Way IECSockets
Powder Coated Steel Housing
Unprotected
19 Inch Rack Mounted
ON/OFF Switch and Power Indication
1008IEC/GB 10 Way IEC socket strip with a hardwired 2m lead and GB (UK) BS1363 moulded plug. Housed in durable powder coated steel, it features an ON/OFF switch and power indication and is suitable for audio/video, IT or datacommunications systems. This socket strip is NOT Surge Protected. |
Download
|
|
110V, 140V & 650V PADs Approved SSI (RTM Series)
|
RTM 150/650 650V PADs 086-047165
RTM 12/140 140V PADs 086-047166
RTM 12/110 110V PADs 086-047167
Solid State Interlocking (SSI) Protection
Two Stage High Current Protection
RTM Series These Network Rail PADS Approved single phase devices with MOV or SAD component technology, are designed for Rail applications to help reduce the failure rate of Trackside Functional Modules (TFMs) during lightning storms. Protection for signals, points, level crossings. |
Download
|
|
12 Channel 4500A EMP Protection (ZOMM108/309/1/12)
|
12 Channel EMP device
250V AC/325V DCrms
1 Active MOV per line
Repetetive Duty 4/20μs 300A
Max 8/20μs Current per Channel 4500A
ZOMM108/309/1/12 - 12 channel device to protect equipment against the effects of EMP. Recommended for Zone 2. Continuous operating voltage AC rms 250V, DC 325V. Maximum Current per Channel 8/20μs 4500A with a leakage current per channel at rated voltage, DC <50μA. |
Download
|
|
13 Amp Low Current EMI Filter (F1/230/13)
|
Low Current Range 13 Amp
Nominal Voltage Rating 230V rms
Surge Handling 8/20μs 19.5kA
Voltage Protection Level Up 900V @ 3kA 8/20μs
Response Time <10ns
F1/230/13 - 13 Amp - Low Current EMI Filter is a stand alone design that can be mounted close to the point of use. Available in single and three phase options. This filter is enclosed in a metal housing to ensure the best possible screening and also has the added benefit of Surge Protection. |
Download
|
|
16 Channel 4500A EMP Protection (ZOMM 131/XXX/1/16 Series)
|
Range of 16 Channel EMP Devices
Continuous Operating Voltage 25V to 280V AC rms
1 Active MOV per line
Repetetive Duty 4/20μs 300A - 600A
Max 8/20μs Current per Channel 1000A - 4500A
ZOMM131/XXX/1/16 Series - A range of 16 channel devices to protect equipment from the effects of EMP. Recommended for Zone 2. Continuous operating voltage 25V to 280V AC rms. Max Current per Channel 8/20μs 1000A to 4500A and leakage current per channel at rated voltage, DC <100μA |
Download
|
|
16 Channel 4500A EMP Protection (ZOMM108/XXX/1/16 Series)
|
Range of 16 Channel EMP Devices
10VAC/12VDC to 120VAC/156VDC rms
1 Active MOV per line
Repetetive Duty 4/20μs 300A
Max 8/20μs Current per Channel 4500A
ZOMM108/XXX/1/16 Series - A range of 16 channel devices to protect equipment against the effects of EMP. Recommended for Zone 2. Continuous operating voltage AC rms 10V to 120V & DC 12V to 156V. Maximum Current per Channel 8/20μs 4500A with a leakage current per channel at rated voltage, DC <50μA |
Download
|
|
19" Surge Protected Network Cabinet (425-1-0050)
|
Rated Voltage Uc 6V DC, 4.2V AC
Lightning Impulse Current 10/350 0.5kA (L/PG)
Discharge Current 8/20 In 0.15kA (L/L) 2.5kA (L/PG)
Fast Response
24 Connection Ports
425-1-0050 - This 19 inch surge protected distribution cabinet protects network equipment from interruptions caused by surge current. This unit has 24 x RJ45 interfaces; all four pairs lines are protected and is designed according to IEC 61643-21; EN61643-21, GB 18802.2 |
Download
|
|
19" Surge Protected POE Network Cabinet (425-1-0051)
|
Rated Voltage Uc 48V DC, 34V AC
Lightning Impulse Current 10/350 0.15kA (L/PG)
Discharge Current 8/20 In 0.15kA (L/L) 2.5kA (L/PG)
Discharge Current 8/20 POE 0.15 (pair/pair)
24 Connection Ports
425-1-0051 - This 19 inch surge protected POE distribution cabinet protects network equipment from interruptions caused by surge current. This unit has 24 x RJ45 interfaces; all four pairs lines are protected and is designed according to IEC 61643-21; EN61643-21, GB 18802.2 |
Download
|
|
2 Channel 15000A EMP Protection (ZOMM 133/XXX/2/2 Series)
|
Range of 2 Channel EMP Devices
Continuous Operating Voltage 110V to 440V AC rms
2 Active MOV Per Line
Repetetive Duty 4/20μs 2500A
Max 8/20μs Current per Channel 15000A
ZOMM133/XXX/2/2 Series - A range of robust 2 channel devices, recommended for Zones 0,1 & 2, to protect equipment against the effects of EMP. Continuous operating voltage 110V to 440V AC rms . Maximum Current per Channel 8/20μs 15000A with a leakage current per channel at rated voltage, DC <250μA. |
Download
|
|
2 Channel 30000A EMP Protection (ZOMM 123/XXX/4/2 Series)
|
Range of 2 Channel EMP Devices
Continuous Operating Voltage AC rms 120V to 440V
4 Active MOV Per Line
Repetetive Duty 4/20μs 5000A
Max 8/20μs Current per Channel 30000A
ZOMM123/XXX/4/2 Series - A range of robust 2 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage AC rms 120V to 440V. Maximum Current per Channel 8/20μs 30000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
2 Channel 6500A EMP Protection (ZOMM 127/XXX/1/2 Series)
|
Range of 2 Channel EMP Devices
Continuous Operating Voltage 50V to 320V AC rms
Continuous current per channel 10A
Repetetive Duty 4/20μs 1000A
Max 8/20μs Current per Channel 6500A
ZOMM127/XXX/1/2 Series - A range of 2 channel devices to protect equipment against the effects of EMP. Recommended for Zone 1 (Internal) *Except Ref: 127/400 and 127/401. Continuous operating voltage 50V to 320V AC rms. Maximum Current per Channel 8/20μs 6500A with a leakage current per channel at rated voltage, DC <100μA |
Download
|
|
2 Channel 6500A EMP Protection (ZOMM 127A/XXX/1/2 Series)
|
Range of 2 Channel EMP Devices
Continuous Operating Voltage 50V to 320V AC rms
Continuous current per channel 20A
Repetetive Duty 4/20μs 1000A
Max 8/20μs Current per Channel 6500A
ZOMM127A/XXX/1/2 Series - A range of 2 channel devices to protect equipment against the effects of EMP. Recommended for Zone 1 (Internal) *Except Ref: 127A/400 and 127A/401. Continuous operating voltage 50V to 320V AC rms. Maximum Current per Channel 8/20μs 6500A with a leakage current per channel at rated voltage, DC <100μA |
Download
|
|
2 Channel 6500A EMP Protection (ZOMM 237/XXX/1/2 Series)
|
Range of 2 Channel EMP Devices
Continuous Operating Voltage 110V to 250V AC rms
1 Active MOV Per Line
Repetetive Duty 4/20μs 600 to 1000AA
Max 8/20μs Current per Channel 4500 to 6500A
ZOMM237/XXX/1/2 Series - A range of 2 channel devices to protect equipment against the effects of EMP. Recommended for Zone 0. Continuous operating voltage 110V to 250V AC rms . Maximum Current per Channel 8/20μs 4500A to 6500with a leakage current per channel at rated voltage, DC <50μA |
Download
|
|
2 MOV Assembly (AZA-524-2-1000)
|
Continuous Operating Voltage Uc 1000V rms
Lightning Current Impulse In 20kA 8/20μs
Residual Voltage Ures 3.6kV approx. at In
Energy Dissipation 500J/pulse
2 Part Epoxy Coating
AZA-524-2-1000 - Rod mounted MOV assembly composed of 2 x MOV metal oxide varistor discs in parallel with support insulators each side. Suits a vairiety of applications including protection of DC power supplies of generator exciters or on-board inverters for rail rolling stock . Heavy duty mounting brackets. 2 part epoxy coating for environmental protection. |
Download
|
|
2 Pole - T123PA-1V+G-1-275R
|
Type 1-Class I/Type 2-Class II/Type 3-Class III- Single Phase-25kA-275VAC
A 25kA single-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
2 Pole - T123PA-1V+G-3-275R
|
Single Phase T1/2/3 Lightning and surge arrester for LPL III and IV
This range of lightning and surge arresters are configured in 3+1 and 1+1 (CT2 according to BS 7671), allowing for installation in TN-S, TN-C-S and TT earthing systems. This configuration is required for TT earthing systems where an RCD is not used, or the surge arrester is installed on the supply side of the RCD. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
2 Pole - T123PA-2V+0-1-275R
|
Single Phase T1/2/3 Lightning and surge arrester for LPL I and II
This range lightning and surge arresters are configured in 4+0 and 2+0 (CT1 according to BS 7671), allowing for installation in TN-S and TN-C-S earthing systems. This configuration is not suitable for use with a TT earthing system. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
2 Pole - T123PA-2V+0-3-275R
|
Single Phase T1/2/3 Lightning and surge arrester for LPL III and IV
This range lightning and surge arresters are configured in 4+0 and 2+0 (CT1 according to BS 7671), allowing for installation in TN-S and TN-C-S earthing systems. This configuration is not suitable for use with a TT earthing system. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
2 Way Surge & Noise Protected Mains Extension Lead (243GBA)
|
2 Way BS1363 Sockets
Tough ABS Plastic
Surge Protected
Noise Filter
Power/Fuse Status Indication
243GBA - Type 3, Class III 2 Way, Surge protected socket strip meets the requirements of BS EN61643-11/12 . Housed in hardwearing ABS with a hardwired 2m lead and BS1363 (UK) moulded plug, featuring a noise filter and mains power/fuse status indication and is ideal for home, office and industrial use. |
Download
|
|
2 Way Surge & RFI Protected Mains Extension Lead (233GBA)
|
2 Way BS1363 Sockets
Tough ABS Plastic
Surge & RFI Protected
Hardwired Lead & BS1363 Plug
Power/Fuse Status Indication
233GBA 2 Way, Surge protected socket strip meets the requirements of BS EN61643-11/12 – Type 3, Class III. With a hardwired 2m lead and BS1363 (UK) moulded plug, and housed in rugged ABS, it features an RFI filter and mains power/fuse status indication and is ideal for home, office and industrial use. |
Download
|
|
2 Way Surge Protected Mains Extension Lead (223GBA)
|
2 Way BS1363 Sockets
Tough ABS Plastic
Surge Protected
Hardwired Lead & BS1363 Plug
Power/Fuse Status Indication
223GBA 2 Way, Surge protected socket strip meets the requirements of BS EN61643-11/12 – Type 3, Class III. With a hardwired 2m lead and BS1363 (UK) moulded plug, and housed in rugged ABS, it features a mains power/fuse status indication and is ideal for home, office and industrial use. |
Download
|
|
2 Way Switched Surge & RFI Protected Extension Lead (232GBA)
|
2 Way BS1363 Sockets
ABS & Aluminium Housing
Surge & RFI Protected
On/Off Switch
Power/Fuse Status Indication
232GBA - 2 Way, Switched, Surge protected socket strip meets the requirements of BS EN61643-11/12 – Type 3, Class III. With a hardwired 2m lead and BS1363 (UK) moulded plug, and housed in tough ABS and Aluminium, it features an RFI filter and mains power/fuse status indication. |
Download
|
|
2 Way Unprotected Mains Extension Lead (203GBA)
|
2 Way BS1363 Sockets
Tough ABS Plastic
Unprotected
Hardwired Lead & BS1363 Plug
Power/Fuse Status Indication
203GBA 2 Way socket strip with a hardwired 2m lead and BS1363 (UK) moulded plug. Housed in rugged ABS, it features mains power/fuse status indication and is ideal for home, office and industrial use. This socket strip is NOT Surge Protected. |
Download
|
|
20 Channel 4500A EMP Protection (ZOMM 124/303/1/20)
|
20 Channel EMP device
110V AC/145V DCrms
1 Active MOV per line
Repetetive Duty 4/20μs 300A
Max 8/20μs Current per Channel 4500A
ZOMM 124/303/1/20 - 20 channel device to protect equipment against the effects of EMP. Recommended for Zone 2. Continuous operating voltage 110V AC rms, 145V DC. Maximum Current per Channel 8/20μs 4500A with a leakage current per channel at rated voltage, DC <50μA |
Download
|
|
24 Channel 1000A EMP Protection (ZOMM 124/XXX/1/24 Series)
|
Range of 24 Channel EMP Devices
Continuous Operating Voltage AC rms 10V to 120V
1 Active MOV Per Line
Repetetive Duty 4/20μs 300A
Max 8/20μs Current per Channel 1000A
ZOMM124/XXX/1/24 Series - A range of robust 24 channel devices to protect equipment against the effects of EMP. Recommended for Zone 2. Continuous operating voltage 10V to 120V AC rms and 12V to 156V DC . Maximum Current per Channel 8/20μs 1000A with a leakage current per channel at rated voltage, DC <50μA. |
Download
|
|
3 Amp Low Current EMI Filter (F1/230/3)
|
Low Current Range 3 Amp
Nominal Voltage Rating 230V rms
Surge Handling 8/20μs 19.5kA
Voltage Protection Level Up 900V @ 3kA 8/20μs
Response Time <10ns
F1/230/3 - 3 Amp - Low Current EMI Filter is a stand alone design that can be mounted close to the point of use. Available in single and three phase options. This filter is enclosed in a metal housing to ensure the best possible screening and also has the added benefit of Surge Protection. |
Download
|
|
3 Pole - T123PA-3V+0-3-275
|
Three Phase T1/2/3 Lightning and surge arrester for LPL III and IV
This range of lightning and surge arresters are configured in 3+0 and 1+0, allowing for installation in TN-C earthing systems. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
3 Pole - T12PA-IT2V+G-3-275R
|
Three Phase T1/2 Lightning and surge arrester for LPL III and IV
This range of lightning and surge arresters are configured in 3+1 and 1+1 arrangement for use in distribution systems using IT earthing, with or without a distributed neutral. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 tested for use in sub-distribution boards. A high-power GDT between the centre point (CP) and earth ensures that there is no earth leakage current, which allows the device to be used in conjunction with insulation monitoring systems. |
Download
|
|
30 Channel 8000A EMP Protection (ZOMM 221-XXX-1-30 Series)
|
Range of 30 Channel EMP Devices
Continuous Operating Voltage AC rms 50V to 280V
1 Active MOV Per Line
Repetetive Duty 4/20μs 1500A
Max 8/20μs Current per Channel 8000A
ZOMM221/XXX/1/30 Series - A range of robust 30 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage AC rms 50V to 280V. Maximum Current per Channel 8/20μs 8000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
33 Channel 1000A EMP Protection (ZOMM 124/XXX/1/33 Series)
|
Range of 33 Channel EMP Devices
Continuous Operating Voltage AC rms 20V to 280V
1 Active MOV Per Line
Leakage Current Per Channel DC <50μA
Max 8/20μs Current per Channel 1000A
ZOMM124/XXX/1/33 Series - A range of robust 33 channel devices to protect equipment against the effects of EMP. Recommended for Zone 2. Continuous operating voltage 20V to 280V AC rms. Maximum Current per Channel 8/20μs 1000A with a leakage current per channel at rated voltage, DC <50μA. |
Download
|
|
4 Channel 10000A EMP Protection (ZOMM 205/XXX/2/4 Series)
|
Range of 4 Channel EMP Devices
Continuous Operating Voltage AC rms 50V to 280V
2 Active MOV Per Line
Repetetive Duty 4/20μs 2000A
Max 8/20μs Current per Channel 10000A
ZOMM205/XXX/2/4 Series - A range of robust 4 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0, 1 & 2. Continuous operating voltage AC rms 50V to 280V. Maximum Current per Channel 8/20μs 10000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
4 Channel 15000A EMP Protection (ZOMM 135/XXX/2/4 Series)
|
Range of 4 Channel EMP Devices
Continuous Operating Voltage 110V to 440V AC rms
2 Active MOV Per Line
Repetetive Duty 4/20μs 2500A
Max 8/20μs Current per Channel 15000A
ZOMM135/XXX/2/4 Series - A range of robust 4 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage 110V to 440V AC rms . Maximum Current per Channel 8/20μs 15000A with a leakage current per channel at rated voltage, DC <250μA. |
Download
|
|
4 Channel 50000A EMP Protection (ZOMM 123/3S16/6/4)
|
4 Channel EMP Device
Continuous Operating Voltage AC rms 690V
6 Active MOV Per Line
Repetetive Duty 4/20μs 5000A
Max 8/20μs Current per Channel 50000A
ZOMM123/3S16/6/4 - A robust 4 channel device to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage AC rms 690V. Maximum Current per Channel 8/20μs 50000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
4 Channel 50000A EMP Protection (ZOMM123/XXX/4/4 Series)
|
Range of 4 Channel EMP Devices
Continuous Operating Voltage AC rms 120V to 440V
4 Active MOV Per Line
Repetetive Duty 4/20μs 5000A
Max 8/20μs Current per Channel 50000A
ZOMM123/XXX/4/4 Series - A range of robust 4 channel devices to protect equipment against the effects of EMP. Recommended for Zones 0,1 & 2. Continuous operating voltage AC rms 120V to 440V. Maximum Current per Channel 8/20μs 50000A with a leakage current per channel at rated voltage, DC <200μA. |
Download
|
|
4 Channel 6500A EMP Protection (ZOMM 127/XXX/1/4 Series)
|
Range of 4 Channel EMP Devices
Continuous Operating Voltage AC rms 50V to 320V
1 Active MOV Per Line
Repetetive Duty 4/20μs 1000A
Max 8/20μs Current per Channel 6500A
ZOMM127/XXX/1/4 Series - A range of robust 4 channel devices to protect equipment against the effects of EMP. Recommended for Zone 1 (except ref 400 and 401). Continuous operating voltage AC rms 50V to 320V. Maximum Current per Channel 8/20μs 6500A with a leakage current per channel at rated voltage, DC <100μA. |
Download
|
|
4 Channel 6500A EMP Protection (ZOMM 127A/XXX/1/4 Series)
|
Range of 4 Channel EMP Devices
Continuous Operating Voltage 50V to 320V AC rms
Continuous current per channel 20A
Repetetive Duty 4/20μs 1000A
Max 8/20μs Current per Channel 6500A
ZOMM127A/XXX/1/4 Series - A range of 4 channel devices to protect equipment against the effects of EMP. Recommended for Zone 1 (Internal) *Except Ref: 127A/400 and 127A/401. Continuous operating voltage 50V to 320V AC rms. Maximum Current per Channel 8/20μs 6500A with a leakage current per channel at rated voltage, DC <100μA |
Download
|
|
4 Pole - T123PA-3V+G-1-275R
|
Three Phase T1/2/3 Lightning and surge arrester for LPL I and II
This range of lightning and surge arresters are configured in 3+1 and 1+1 (CT2 according to BS 7671), allowing for installation in TN-S, TN-C-S and TT earthing systems. This configuration is required for TT earthing systems where an RCD is not used, or the surge arrester is installed on the supply side of the RCD. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
4 Pole - T123PA-3V+G-3-275R
|
Three Phase T1/2/3 Lightning and surge arrester for LPL III and IV
This range of lightning and surge arresters are configured in 3+1 and 1+1 (CT2 according to BS 7671), allowing for installation in TN-S, TN-C-S and TT earthing systems. This configuration is required for TT earthing systems where an RCD is not used, or the surge arrester is installed on the supply side of the RCD. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
4 Pole - T123PA-4V+0-1-275R
|
Three Phase T1/2/3 Lightning and surge arrester for LPL I and II
This range lightning and surge arresters are configured in 4+0 and 2+0 (CT1 according to BS 7671), allowing for installation in TN-S and TN-C-S earthing systems. This configuration is not suitable for use with a TT earthing system. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
4 Pole - T123PA-4V+0-3-275R
|
Three Phase T1/2/3 Lightning & Surge arrester for LPL III & IV
This range lightning and surge arresters are configured in 4+0 and 2+0 (CT1 according to BS 7671), allowing for installation in TN-S and TN-C-S earthing systems. This configuration is not suitable for use with a TT earthing system. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection. |
Download
|
|
4 Pole - T12PA-IT3V+G-3-440R
|
Three Phase T1/2 Lightning and surge arrester for LPL III and IV
This range of lightning and surge arresters are configured in 3+1 and 1+1 arrangement for use in distribution systems using IT earthing, with or without a distributed neutral. These arresters are designed for use at the boundary of LPZ 0 to LPZ 1 in structures of LPL III and LPL IV (Class III and IV Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 tested for use in sub-distribution boards. A high power GDT between the centre point (CP) and earth ensures that there is no earth leakage current, which allows the device to be used in conjunction with insulation monitoring systems. |
Download
|
|
4 Pole - T23PA-3V+G-275R
|
Three Phase T2/3 Surge arrester
Designed for installation at the boundary of LPZ 1 -2 or higher, to protect low voltage equipment from surge damage. Designed according to IEC 61643-11, this device is a pluggable, modular, Class II SPD for TT, TN-S and TN-C-S power supply system. This surge protective device is usually installed in a distribution board or other control panel, protecting devices or equipment downstream. |
Download
|
|
4 Way Surge & Noise Protected Mains Extension Lead (443GBA)
|
4 Way BS1363 Sockets
Tough ABS Plastic
Surge Protected
Noise Filter
Power/Fuse Status Indication
443GBA 4 Way, Surge protected socket strip meets the requirements of BS EN61643-11/12 – Type 3, Class III. Housed in rugged ABS with a hardwired 2m lead and BS1363 (UK) moulded plug, it features a noise filter and mains power/fuse status indication and is ideal for home, office and industrial use. |
Download
|