Skip to main content

Search documents

Type 1 - Class I - Single Phase - 1 Pole - 12.5kA - 320VAC 

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use on the power supply lines, which operate a TN-C, TN-S and TT earthing system.

Type 1 - Class I / Type 2 - Class II - Single Phase - 1 Pole - 12.5kA - 500VAC

These devices are single-pole lightning and surge arresters Type 1+2 according to IEC EN 61643-11.

Type 1 - Class I - Single Phase - 50kA - 255VAC

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use in systems that use TN-C earthing. For TNS and TT systems it is necessary to combine these arresters with an additional module designed for Neutral – Earth use.

Type 1 - Class I - Single Phase - 50kA - 440VAC

For use in the LPZ Concept at the boundaries of LPZ 0 – 1

Designed mainly for use in systems that use TN-C earthing. For TNS and TT systems it is necessary to combine these arresters with an additional module designed for Neutral – Earth use.

Type 1-Class I/Type 2-Class II/Type 3-Class III- Single Phase-25kA-275VAC

A 25kA single-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use at the boundary of LPZ 0 to LPZ 1 in structures of LPL I and LPL II (Class I and II Lightning Protection System) as a Type 1 lightning arrester. They are also Type 2 and Type 3 tested for use in sub-distribution boards and local equipment protection.

Type 1 - Class I / Type 2 - Class II - Single Phase - 2 Pole - 12.5kA -12.5kA - 275VAC

Recommended for use in the Lightning protection zones concept at the boundaries of LPZ 0-1. These lightning arresters are for use mainly in the power supply lines, which are operated as TN-S system.

Type 1 - Class I / Type 2 - Class II - Single Phase - 2 Pole - 12.5kA - 25kA - 230VAC

The T1PDM1/12.5/25/230 and the T1PDM1/12.5/25/230R are two-pole, Type 1 and 2 MOV + GDT lightning arrester according to EN 61643-11 and IEC 61643-11. The use of these arresters is mainly in the power supply lines, which are operated as TN-S and TT systems.

Type 1 - Class I / Type 2 - Class II - Single Phase - 12.5kA - 275VAC

A single-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use in industrial & administration buildings, schools, supermarkets and cathedrals.

Type 1 - Class I / Type 2 - Class II - Three Phase - 12.5kA - 230VAC

The T1PDM3/12.5/230 and T1PDM3/12.5/230R (Remote Version) are lightning arresters type 1 or type 2 according to EN 61643-11.

Type 1 - Class I / Type 2 - Class II - Three Phase - 12.5kA -12.5kA - 275VAC / 350VDC

The T1PDM3/12.5/12.5/230 and the T1PDM3/12.5/12.5/230R (Remote Version) are lightning arresters type 1 or type 2 according to EN 61643-11. 

These devices are mainly intended for use in TNS, TNC-S systems.

Type 1 - Class I / Type 2 - Class II - Three Phase - 12.5kA -50kA - 275VAC

The T1PDM3/12.5/50/230 and the T1PDM3/12.5/50/230R are Type 1 and 2 lightning arrester according to EN 61643-11. 

The devices are mainly intended for use in TNS, TNC-S or TT systems.

Type 1 - Class I / Type 2 - Class II - Three Phase - Four Pole - 7kA - 25kA - 320VAC / 350VDC

The T1PDM3/7/25/320 and T1PDM3/7/25/320R (Remote Version) are four-pole, metal oxide varistor surge arrester combined with gas discharge tube, Type 1/2 according to EN 61643-11 and IEC 61643-11.

Type 1 - Class I / Type 2 - Class II - Three Phase - L/N 12.5 kA - N/PE 50kA - 275VAC  

A 12.5kA three-phase MOV+GDT lightning and surge arrester. Designed for TNS, TNC-S and TT earthing systems. For use in industrial & administration buildings, schools, supermarkets & cathedrals.

Type 1 - Class I / Type 2 - Class II - Three Phase - L/N 25kA - N/PE 100kA - 275VAC

A 25kA three-phase MOV+GDT lightning and surge arrester. Dsigned for TNS, TNC-S and TT earthing systems. For use in hospitals, banks, mobile operator stations, water-works, power plants, airport buildings for air traffic control.

Like this product? Click here to see our newer version T1ZH3/25/100/230R

Type 1 - Class I Type 2 - Class II - 12.5kA - 3 x 480V AC

The T1SP3/IT/12.5/400R lightning surge arrester type 1 + 2 designed for the IT network 3 x AC 400 V without neutral conductor. The recommended use for the T1SP3/IT/12.5/400R is in heavy industry, rolling mills, machinery, etc. 

Type 1 - Class I Type 2 - Class II - 12.5kA - 3 x 500V AC

The T1SP3/IT/12.5/500R lightning surge arrester type 1 + 2 designed for the IT network 3 x AC 500 V without neutral conductor. The recommended use for the T1SP3/IT/12.5/500R is in heavy industry, rolling mills, machinery, etc. 

Type 1 - Class I / Type 2 - Class II - Three Phase - 12.5kA -12.5kA - 275VAC

This Type 1/2 (Class I/II) surge protective device is for installation atThis Type 1/2 (Class I/II) surge protective device is for installation at LPZ 0A-2 or higher and is usually installed in the distribution-box or feeder bus of UPS, protecting devices or equipment downstream.

Type 1 - Class I / Type 2 - Class II - Three Phase - 25kA -100kA - 255VAC

This Type 1/2 (Class I/II) surge protective device is designed to protect low voltage devices from lightning and surge damages.

This product is our new version of the popular T1SP3/25/100/230R

Type 1 - Class I / Type 2 - Class II - Three Phase - 50kA -100kA - 380VAC

This Type 1/2 (Class I/II) surge protective device is designed to protect low voltage devices from lightning and surge damages.

Type 1 - Class I / Type 2 - Class II - 12.5kA - 600VDC

The T1PV2/12.5/600 & T1PV2/12.5/600R  (Remote Version) are lightning arrester type 1+2 according to EN 61643-11. It is designed for protection of positive and negative busbars of photovoltaic systems against the surge effects.

Type 1 - Class I / Type 2 - Class II - 12.5kA - 800VDC

The T1PV2/12.5/800 & T1PV2/12.5/800R (Remote Version) are lightning arrester type 1+2 according to EN 61643-11. It is designed for protection of positive and negative busbars of photovoltaic systems against the surge effects.

T1/2, DC Lightning and surge arrester for LPL I and II

Type 1+2 Lightning and Surge arrester recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0-2 for equipotential bonding of positive and negative busbars of photovoltaic systems and elimination of transient overvoltages originating from atmospheric discharges or switching processes.